REScheck
About REScheck
REScheck is the program a builder or designer runs to prove that a house design meets the residential energy code before the plans go to the permit office. You describe the building envelope, meaning every ceiling, wall, window, door, floor and slab edge with its area and its insulation value, pick the code edition the jurisdiction enforces, and a bar at the bottom of the window tells you whether the design passes and by how much. The output is a compliance certificate and an inspection checklist that go into the permit package, which is why plan reviewers recognise the format on sight.
The desktop edition is the one that runs without a connection and keeps project files on your own drive. It has been frozen, and the code editions it carries are the last it will ever get, with anything newer living only in the browser version.
For the many jurisdictions still enforcing an older edition that is a non-issue, and for a laptop on a job site without reliable signal it is the only option. Know which edition your permit office wants before deciding whether the frozen list reaches it.
Project first, then the envelope
The REScheck Project tab sets the stage. You choose the code, which includes the base IECC editions and the amended versions adopted by individual states, then the location by state and county, which fixes the climate zone and with it the requirements the rest of the program will test against. Construction type, conditioned floor area and the compliance method round it out. Get the county wrong and every number afterwards is checked against the wrong zone, so this screen deserves more attention than its size suggests.
The Envelope tab is the real work. Each assembly is added as a row with a type picked from a list, a gross area, and the insulation described as cavity R-value plus continuous R-value, or as a U-factor if you have one from a product data sheet.
Windows and glass doors take a U-factor and a solar heat gain coefficient per unit. Slabs take a perimeter and an insulation depth. The program subtracts openings from wall areas itself when you nest them properly, and fails to when you do not, which is the single most common cause of a design that mysteriously fails.
The compliance bar and the trade-off behind it
At the bottom sits a bar that reads Passes or Fails with a percentage, better or worse than code. REScheck arrives at that number through the UA trade-off method. It multiplies each assembly’s area by its U-factor, sums the result for your design, does the same for a reference house with every assembly exactly at the prescriptive minimum, and compares the two totals. A wall insulated beyond code can make up for windows that fall short, which is the whole reason to use the program rather than the prescriptive table.
What it will not trade is equipment. Under the current editions a high-efficiency furnace earns no envelope credit, and the Mechanical tab exists to record what is installed rather than to help you pass. That surprises people who remember older editions where it did count, and the program is quietly correct about it.
The requirements the bar does not test
The Requirements tab lists the mandatory items the UA calculation does not test, air sealing, duct insulation, lighting efficacy and the rest, with a checkbox for each and a note on how it is verified. Air leakage and duct tightness are confirmed by testing on site, not by anything you type here, and REScheck says so in the checklist rather than pretending otherwise.
Reports and the file you hand over
REScheck reports come out as the Compliance Certificate, the Inspection Checklist the field inspector works from, and a small panel certificate meant to be posted on the electrical panel listing the installed values. All three print or export as PDF, which is the form the permit office expects.
Project files save with their own extension and reopen on any machine running the program, and an older file opens in a newer build without complaint.
Where the desktop edition stops
The desktop REScheck knows nothing about the newest code editions, and no update will teach it. It does not model energy use, so there is no annual energy figure and no comparison between two designs beyond the percentage on the bar. It covers detached houses and low-rise multifamily, and nothing taller, which belongs to a sibling program for commercial work.
The interface is a grid of rows and drop-downs that has not changed in years, and it does not need to. What trips newcomers is not the screen but the takeoff, the business of measuring gross wall area, net wall area and ceiling area correctly from the plans before entering anything.
The program checks what you type. It cannot check what you measured.
Conclusion
REScheck is for builders, designers and plan reviewers who need the standard compliance package for a house under the code editions the desktop version carries, and who want it produced offline from a file they control. For that job it is direct and the output is exactly what the permit office expects.
If your jurisdiction has moved to an edition the frozen program does not have, or you want energy modelling rather than a pass or fail, this version is the wrong one and a simulation tool is the right one. For everyone else the takeoff is the hard part, and the program is the easy one.
Pros & Cons
- UA trade-off lets strong assemblies compensate for weak ones instead of forcing the prescriptive table
- State-amended code editions and county-based climate zones built in
- Compliance certificate, inspection checklist and panel certificate print straight from the project
- Runs offline with project files on your own drive
- Frozen, so the newest code editions exist only in the browser version
- No energy modelling, only a pass or fail percentage
- Equipment efficiency earns no credit under current editions
- Easy to fail a design by entering gross and net wall areas incorrectly
Frequently asked questions
Usually an area problem. If windows and doors were not nested under their wall, the wall area is counted twice, or the county set the wrong climate zone. Check the Project tab and the wall rows before touching insulation values.
Not under the current code editions. The Mechanical tab records the equipment, but the UA trade-off compares envelope only.
No. Those are verified by testing on site, and the Requirements tab lists them as items for the inspector rather than calculating them.
Yes. Project files reopen in newer builds without conversion, and the code edition saved with the project is kept, so a file from an earlier permit can be duplicated for a similar house.